Add to Cart
Analog Load cell amplifier 0-5V/0-10V/4-20mA load cell signal conditioner
Single channel load cell signal amplifier FSC can work with all our load cell sensors and torque transducers with mV/V configuration to deliver -5-5V / 0-3.3V / 0-5V / 0-10V / 0-20mA / 4-20mA for further data acquisition.Analog load cell conditioner FSC is mainly used for single load cell signal amplification, using Zero adjustment and Gain adjustment for signal calibration. Mating connector along with 1m-long cable is provided for easy connection.
Specifications
Function | Turn mV signal into V or mA signal |
Accuracy | 0.1% |
Power supply | 24V DC or 12V DC |
Output signal | -5-5V,-10-10V,0-5V,0-10V,4-20mA,0-20mA |
Excitation for load cell | 5V DC |
Applicable sensitivity | 0.6mV/V~3mV/V |
Working temperature | -10...+60oC |
Material of housing | Aluminum |
Ingress protection | IP50 |
Cable | Ø5*1000mm cable with mating connector |
Wiring | 3-wire connection Red---Power+ Green---Output+ Black---Power-/Output- |
Wiring example for load cell with amplifier FSC
Dimensions(in mm)