Ask Latest Price
Place of Origin :China
Brand Name :Forsentek
Model Number :FH7A
Delivery Time :3~25 working days
Payment Terms :T/T,Western Union or Paypal
Supply Ability :5900pcs/month
MOQ :5pcs
Packaging Details :Carton
Usage :Weight measurement
Type :Single Point Load Cell
Output :Analog Sensor
Capacity :60/100/200/300/500/600/800/1000kg
Accuracy level :C3
Contact Now

Add to Cart

Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
View Product Description

Single Point Load Cell 1000kg 600kg 500kg 300kg 200kg 100kg Weighing Sensor

High Accuracy Single Point Load Cell FH7A is strain gauge based delivering 2.0mV/V rated output from the full wheatstone bridge with 0.015% non-linearity error of the full scale. Weight Sensor FH7A is off-center load compensated for up to 800x800mm platform which makes weight transducer FH7A ideal for single-cell large-platform scales. Temperature compensation process guarantees stable performance over a wide of working temperature. Environmentally sealed with potting compound to ensure durability. Load Cell Sensor FH7A offers 1000kg / 800kg / 600kg / 500kg / 300kg / 200kg / 100kg / 60kg (132lb / 220lbf / 440lb / 660 lbf / 1.1klbs / 1320lbf / 1760lb / 2.2klbf) eight rated capacities to choose from, you may find weighing sensor FH7A interchangeable with Sentronik 7342, anyload 108CA, VPG Tedea-Huntleigh 1263, Coti Global CG-50-2, Transcell FAV, Zemic L6G, Optima OP-305, ptglobal PTASP6-G. Typical applications of weight sensor FH7A are for example platform scales, automated weighing stations, food packaging machines, intelligent warehouse weighing system and so on.

Single Point Load Cell 1000kg 600kg 500kg 300kg 200kg 100kg Weighing Sensor

Dimensions

Single Point Load Cell 1000kg 600kg 500kg 300kg 200kg 100kg Weighing Sensor

Ordering code: FH7A-60kg, FH7A-100kg, FH7A-200kg, FH7A-300kg, FH7A-500kg, FH7A-600kg, FH7A-800kg, FH7A-1000kg

Specifications

Rated capacity

60kg / 132 lb

100kg / 220 lbf

200kg / 440 lb

300kg / 660 lbf

500kg / 1.1klbs

600kg / 1320 lbf

800kg / 1760 lb

1000kg / 2.2klbf

Rated output 2.0mV/V
Excitation 3-15V
Zero balance ±0.1mV/V
Nonlinearity ±0.015% R.O.
Hysteresis ±0.015% R.O.
Nonrepeatability ±0.01% R.O.
Creep(30min) ±0.02% R.O.
Safe overload 150% F.S.
Ultimate overload 200% F.S.
Compensated temperature 0...+40oC
Operating temperature -20...+60oC
Temperature shift zero ±0.02% R.O./10oC
Temperature shift span ±0.02% R.O./10oC
Input resistance 405±100 ohms
Output resistance 350±5 ohms
Insulation resistance >5000M ohms
Ingress protection IP65
Material of element Aluminum alloy
Cable Ø5*2000mm 4-core shielded
Wiring code Red--Excitation+ Black--Excitation-
Green--Signal+ White--Signal-


Single Point Load Cell 1000kg 600kg 500kg 300kg 200kg 100kg Weight Transducer

Single Point Load Cell 1000kg 600kg 500kg 300kg 200kg 100kg Weighing Sensor

A single point load cell is a transducer that converts mechanical force into electrical signal which is proportional to the weight(or force) being applied.The measured load or force causes deformation of the measuring element(elastic body),the bonded strain gauge deforms accordingly which will cause the resistance change of the wheatstone bridge,under constant power supply, the output signal between Sig+ and Sig- will change proportionally, thus the load/force can be measured by measuring the output signal from the load cell which is normally within 0-30mV.Overloading is the most common cause of loadcell failure, a load cell is just like a spring in certain aspects, which will be damaged if overstretched. A machanical stop(refer to below picture) can be used to protect the sensor from excessive deformation. The gap distance can be determined by loading the sensor with rated capacity,then adjust the meachnical stop to reach the bottom of the transducer.In most cases,the load cell will be used to measure load at 30-60% of the full scale,thus the gap distance can also be adjusted using reference load a little higher than the target load to be measured instead of the rated capacity.

Single Point Load Cell 1000kg 600kg 500kg 300kg 200kg 100kg Weighing Sensor

Single Point Load Cell 1000kg 600kg 500kg 300kg 200kg 100kg Weighing Sensor

Single Point Load Cell 1000kg 600kg 500kg 300kg 200kg 100kg Weighing Sensor

Click here to download datasheet

China Single Point Load Cell 1000kg 600kg 500kg 300kg 200kg 100kg Weighing Sensor for sale

Single Point Load Cell 1000kg 600kg 500kg 300kg 200kg 100kg Weighing Sensor

Inquiry Cart 0